Serial-Device-Servers-NPort-5150AI-M12-NPort-5250AI-M12-NPort-5450AI-M12-Series-Moxa-vietnam.jpg

Serial Device Servers NPort 5150AI-M12/NPort 5250AI-M12/NPort 5450AI-M12 Series Moxa vietnam


Features and Benefits 

  • Speedy 3-step web-based configuration
  • COM port grouping and UDP multicast applications
  • Real COM/TTY drivers for Windows and Linux
  • Standard TCP/IP interface and versatile TCP and UDP operation modes
  • Complies with all EN 50155 mandatory test items*
  • M12 connector and IP40 metal housing
  • 2 kV isolation for serial signals
    *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf

 

Introduction

The NPort 5000AI-M12 serial device servers are designed to make serial devices network-ready in an instant, and provides direct access to serial devices from anywhere on the network. Moreover, the NPort 5000AI-M12 is compliant with EN 50121-4 and mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration,  making them suitable for rolling stock and wayside applications where high levels of vibration exist in the operating environment.

 

3-step Web-based Configuration

The NPort 5000AI-M12’s 3-step web-based configuration tool is straightforward and user-friendly. The NPort 5000AI-M12’s web console guides users through 3 simple configuration steps that are necessary to activate the serial-to-Ethernet application. With this speedy 3-step web-based configuration, a user only needs to spend an average of 30 seconds to complete the NPort settings and enable the application, saving a great amount of time and effort.

 

Easy to Troubleshoot

NPort 5000AI-M12 device servers support SNMP, which can be used to monitor all units over Ethernet. Each unit can be configured to send trap messages automatically to the SNMP manager when user-defined errors are encountered. For users who do not use SNMP manager, an e-mail alert can be sent instead. Users can define the trigger for the alerts using Moxa’s Windows utility, or the web console. For example, alerts can be triggered by a warm start, a cold start, or a password change.

Dimensions (unit = mm)

 

Pin Assignment

Ethernet Interface
Number of Ports 1
Speed 10/100 Mbps, auto MDI/MDIX
Connector M12 D-coded 4-pin female connector
Serial Interface
Number of Ports 1, 2, 4
Serial Standards RS-232/422/485
Connector DB9 male
RS-485 Data Direction Control ADDC® (Automatic Data Direction Control)
Serial Communication Parameters
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS and DTR/DSR (RS-232 only), XON/XOFF
Baudrate 50 bps to 921.6 kbps
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Software
Network Protocols ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, IGMP V1/2, ARP, LLDP
Configuration Options Web Console (with new Quick Setup), Telnet Console, Windows Utility
Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY Drivers SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Linux Real TTY Drivers Linux 2.4.x, 2.6.x, 3.x
Physical Characteristics
Housing Metal, IP40 protection
Weight 686 g (1.51 lb)
Dimensions 80 x 216.6 x 52.9 mm (3.15 x 8.53 x 2.08 in)
Environmental Limits
Operating Temperature Standard Models: -25 to 55°C (-13 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Power Requirements
Input Voltage 12 to 48 VDC 
Note: Compliant with EN 50155 on 24/48 VDC
Input Current NPort 5150AI-M12: 310 mA @ 12 VDC
NPort 5250AI-M12: 360 mA @ 12 VDC
NPort 5450AI-M12: 440 mA @ 12 VDC
Connector M12 5-pin male connector
Standards and Certifications
Safety UL 60950-1
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Rail Traffic EN 50155*, EN 50121-4 
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf
Vibration IEC 60068-2-6
Reliability
Alert Tools Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger Built-in WDT (watchdog timer)
MTBF (mean time between failures)
Time NPort 5150AI-M12: 789,341 hrs
NPort 5250AI-M12: 639,622 hrs
NPort 5450AI-M12: 467,777 hrs
Standard Telcordia (Bellcore) Standard TR/SR
Warranty
Warranty Period 5 years
Details www.anhnghison.com