DATA CENTRE CABLE – CÁP CHUYÊN DỤNG CHO TRUNG TÂM DỮ LIỆU

Eland Cables is a specialist power cable supplier supporting hyperscale and enterprise data centre builds, refurbishments and maintenance projects around the world.

With an ever-growing demand for data and critical services that must maintain operation all day, every day, 365 days of the year, the power network supporting the servers, switches and climate control functions has to be robust and resilient. Scheduled downtime must be kept to a minimum.

Data centre power cable requirements run from the energy grids all the way into server rooms, connecting sub-stations with MV cables to generators and transformers stepping down to LV power when it enters the building to power HVAC, fire suppression systems and the data centre servers themselves. Increasingly, data centre operators look for eco-friendly, carbon-neutral solutions to the power-intensive demands of the building, so solar, natural cool-air, and wind-powered renewables are a common part of the data centre set-up.

Cable Portfolio for  Data centre :

  • MEDIUM VOLTAGE - BRITISH STANDARD ARMOURED

3.3/6.6kV | 6.35/11kV | 12.7/22kV |19/33kV | 26/45kV

Eland Cable - BS 6622 (PVC) and BS 7835 (LSZH)

Single core AWA or multi core SWA armoured cable suitable for direct burial. Normally supplied with Class 2 stranded copper conductors but Aluminium also available. Suitable for laying direct into the ground.

  • MEDIUM VOLTAGE - EUROPEAN STANDARD UNARMOURED

6/10kV | 12/20kV | 18/30kV | 26/45kV

 Eland Cable - N2XSY (PVC) and N2XSH (LSZH) (COPPER)

Eland Cable - NA2XSY (PVC) and NA2XSH (LSZH) (ALUMINIUM)

Single core XLPE insulated and PVC or LSZH sheathed power cable with copper wire screen suitable for outdoor static installation without heavy mechanical or tensile strain.

Eland Cable - N2XS2Y (COPPER) and NA2XS2Y (ALUMINIUM)

Single core XLPE insulated and Medium Density Polyethylene (MDPE) sheathed cable with copper wire screen suitable for in-ground installation or in cable ducts with water present. Optional dual longitudinal water-blocking tapes available to prevent water ingress.

  • LOW VOLTAGE - BRITISH STANDARD ARMOURED- 0.6/1kV

Eland Cable - BS5467 (PVC) and BS6724 (LSZH)

Low voltage armoured power cables suitable for direct burial. Single core to 1000mm2 and

multi-core to 400 mm2 with copper conductors supplied as standard. Also available with

Aluminium conductors. BASEC Approved.

  • LOW VOLTAGE - EUROPEAN STANDARD UNARMOURED- 0.6/1kV

Eland Cable - N2XY / N2XH (COPPER) and NA2XY / NA2XH (ALUMINIUM) (PVC / LSZH)

Low voltage European power cable with Class 1 solid (to 25mm2) or Class 2 stranded conductor. Single core and multi core configurations, available with or without green/ yellow earth core (-J or -O). Not suitable for direct burial.

Eland Cable - N2XH FLEX ENHANCED (COPPER) (LSZH)

Custom designed by The Cable Lab for our data centre projects, this halogen free cable offers enhanced flexibility & improved strippability to aid swift installation into compact and restricted spaces, saving time & effort. BSI Kitemark tested. KEMA Approved.

Eland Cable - N2XCH (COPPER) NA2XCH (ALUMINIUM) (LSZH)

Class 1 solid or Class 2 stranded conductors with copper wires and tape concentric conductor. Suitable for installation in plaster but not for direct burial without additional mechanical protection.

  • LOW VOLTAGE FLEXIBLE - EUROPEAN HARMONISED

Eland Cable - H07ZZ-F (LSZH) (RUBBER)

Robust multi core cable offering flexibility with LSZH rubber sheathing for applications under moderate amounts of stress. Used extensively throughout data centres to power server cabinets and UPS. BSI Kitemark tested.

Eland Cable - H07RN-F and H07RN8-F (RUBBER)

Heavy-duty EPR insulated flexible rubber cable for trailing power applications under moderate mechanical and thermal stresses. H07RN8-F suitable for permanent submersion in water to 10m.

Eland Cable - RV-K (PVC)

Flexible low voltage power distribution cable with water-resistant PVC sheathing available as single core or multi-core. Suitable for installation outdoors and in ducts

Eland Cable - RZ1-K (LSZH)

Flexible power and control cable with green LSZH Polyolefin sheath. Designed for internal fixed installation but UV resistant for exposure to sunlight. Single core and multicore cable.

  • LOW VOLTAGE – EARTH

Eland Cable - 6491B - H07Z-R (LSZH)

Single core LSZH cable used in fixed wiring protected installations. Available as standard in sizes up to 630mm2 and in 11 insulation colours. BASEC Approved.

  • LOW VOLTAGE FLEXIBLE - PANEL WIRING

Eland Cable - 2491B - H07Z-K / H07Z-K (LSZH)

Single core LSZH cable used for power switchgear panels in applications where PVC 2491X or tri-rated are not suitable. Available in 11 insulation colours. BASEC Approved.

  • INSTRUMENTATION CABLE - 300V (90V and 500V on request)

Eland Cable - BS EN 50288-7

European standard instrumentation cables with LSZH sheathing. Options for collective screening and PiMF. Pairs, triples and quad formations. Other insulation and sheathing materials available.

 

Eland Cable - BS 5308

British standard (now withdrawn and superseded by BS EN 50288-7) still extensively specified. Part 1 Type 1 (XLPE insulation, LSZH or Silicone sheathing) or Part 1 Type 2 (with SWA) available with collective (CAM) or individual and collective (ICAM) screening. Other insulation and sheathing materials available.

  • FIRE PERFORMANCE CABLE

STANDARD / ENHANCED GRADE

Fire resistant cables for delivering power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems covered under BS5839-1, BS5266 and BS8519. Also available with augmented fire resistance to maintain circuit integrity for up to 120 mins in building with phased evacuation.

 