Fieldbus Interface Boards CB-602I Series Moxa vietnam
Hãng sản xuất: Moxa
Fieldbus Interface Boards CB-602I Series Moxa vietnam
Features and Benefits
- CAN 2.0A and CAN 2.0B supported
- Two independent CAN communication ports
- CAN transfer rate up to 1 Mbps
- 2 kV electrical isolation
- LED for transmit/receive status on each port
- Optional 120 ohm terminal resistor for CAN bus network
- DLL library and examples included
- Windows drivers provided
Overview
Moxa’s new CB-602I CAN (Controller Area Network) interface board supports the PC/104-Plus interface. Optional DB9 and DB25 connection cables are available for connecting to CAN interface device. The CB-602I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CB-602I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
Dimensions
• Hardware | |
Connector | 20-pin box header |
CAN Controller | NXP SJA1000 |
CAN Transceiver | PCA82C251 |
CAN Specification | CAN 2.0 A/B |
Signal Support | CAN_H, CAN_L, GND |
Transfer Rate | 1 Mbps |
Max. Number of Boards per PC | 4 |
Electrical Isolation | 2 kV |
Termination Resistor | 120 ohms (selected by jumper) |
• Driver Support | |
Windows | Windows 2000, Windows XP/2003/Vista/2008 (x86/x64) |
Note: Please refer to Moxa’s website for the latest driver support information. | |
• Software | |
Libraries | Visual C/C++, Borland C/C++ |
• Environmental Limits | |
Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class B |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4 |
• MTBF (mean time between failures) | |
Time | 248,563 hrs |
Standard | Telcordia (Bellcore) TR/SR |
• Power Requirements | |
Input Current | 380 mA @ 5 VDC |
• Warranty | |
Warranty Period | 5 years |
Details | www.anhnghison.com |