Features and Benefits
- RM-1050-T: 10 channel-to-channel isolated DIs, 110 VDC, sink/source type
- RM-1602-T: 16 digital inputs, 24 VDC, sink/source type
- RM-2600-T: 16 digital outputs, 24 VDC, sink-type
- RM-3802-T: 8 analog inputs, 4 to 20 mA
- RM-3810-T: 8 analog inputs, 0 to 10 V
- KM-2430-T: 4-port unmanaged Ethernet switch module
Fast Track Integration for Wayside Condition Monitoring and Preventive Maintenace
This white paper will discuss how railway operators are adopting increasingly sophisticated condition-based maintenance regimes to control costs and improve track performance, some of the key difficulties system integrators need to overcome when deploying wayside condition monitoring systems for railway preventive maintenance, and how using a single condition monitoring platform can save time and costs for deployment and maintenance.
Railway Preventive Maintenance Solutions Flyer
See how Moxa's ioPAC 8500 RTU controllers make railway preventive maintenance easy. The RTUs provide extremely accurate data, giving engineers the information they need to identify anomalous conditions, before failures occur. The ioPAC 8500 RTUs are also designed to work reliably in harsh environments, and modules can be easily replaced to shorten system downtime.
RM-1602-T Specifications | |
Digital Inputs | 16 channels, 24 VDC, sink/source type |
On | 10 to 30 VDC |
Off | 0 to 3 VDC |
Input Impedance | 3 kilo-ohms (typical) |
Common Type | 8 points per 2 COMs |
Response Time | 10 ms |
Isolation | 3k VDC or 2k Vrms |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 7 mA @ 24 VDC |
Wiring | I/O cable, 14 AWG (max.) |
MTBF | 4,132,863 hrs (Standard: Telcordia SR332) |
RM-1050-T Specifications | |
Digital Inputs | 10 channels, 110 VDC, channel-to-channel isolation |
On | 50 to 175 VDC |
Off | 0 to 15 VDC |
Input Impedance | 120 kilo-ohms (typical) |
Response Time | 10 ms |
Isolation | 3k VDC or 2k Vrms |
Channel-to-Channel Isolation | 2.5k VDC |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 7 mA @ 24 VDC |
Wiring | I/O cable, 14 AWG (max.) |
MTBF | 3,993,435 hrs (Standard: Telcordia SR332) |
RM-2600-T Specifications | |
Digital Outputs | 16 channels, 24 VDC, sink-type |
Output Impedance | 120 milli-ohms (typical) |
Current Rating | 200 mA per channel |
Off-state Resistance | 500 kilo-ohms (typical) |
Response Time | 10 ms |
Over Current Protection | 2.6 A (4 channels @ 650 mA) |
Isolation | 3k VDC or 2k Vrms |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 10 mA @ 24 VDC |
Wiring | I/O cable, 14 AWG (max.) |
MTBF | 4,440,241 hrs (Standard: Telcordia SR332) |
RM-3802-T Specifications | |
Analog Inputs | 8 channels, differential |
Input Range | 4 to 20 mA |
Input Impendence | 120 ohms |
Resolution | 16 bits, 0.24 μA/bit |
Accuracy | ±0.1%, FSR @ 25°C ±0.3%, FSR @ -40°C and 75°C |
Sampling Rate | • All channels: 12 samples/sec • Per channel: 1.5 samples/sec |
Isolation | 3k VDC or 2k Vrms |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 78 mA @ 24 VDC |
Wiring | I/O cable, 14 AWG (max.) |
MTBF | 1,222,361 hrs (Standard: Telcordia SR332) |
RM-3810-T Specifications | |
Analog Inputs | 8 channels, differential |
Input Range | 0 to 10 VDC |
Input Impendence | 10 mega-ohms (min.) |
Resolution | 16 bits, 0.15 μA/bit |
Data Format | 16-bit integer (2’s complement) |
Accuracy | ±0.1%, FSR @ 25°C ±0.3%, FSR @ -40°C, 75°C |
Sampling Rate | • All channels: 12 samples/sec • Per channel: 1.5 samples/sec |
Isolation | 3k VDC or 2k Vrms |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 78 mA @ 24 VDC |
Wiring | I/O cable, 14 AWG (max.) |
MTBF | 1,225,957 hrs (Standard: Telcordia SR332) |
KM-2430-T Specifications | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for Flow Control |
Processing Type | Store and Forward |
Interface | Front cabling, M12 connector, 10/100BaseT(X) auto negotiation speed |
Operating Temperature | -40 to 75°C (-40 to 176°F) |
Input Current | 20 mA @ 24 VDC |
MTBF | 3,873,592 hrs (Standard: Telcordia SR332) |
Common Specifications | |
• Power Requirements | |
Input Voltage | 12 to 36 VDC |
• Environmental Limits | |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 55032, EN 55024 |
EMI | FCC Part 15 Subpart B Class A, CISPR 32, CISPR 16-1-2, 16-2-1, 16-2-3, EN 61000-6-4 |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1000 MHz: 10 V/m 1400 MHz to 2100 MHz: 3 V/m 2100 MHz to 2700 MHz: 1 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 2 kV (L-PE), 1 kV (L-L); Signal: 1 kV (9-slot version) IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF: 30 A/m |
Rail Traffic | EN 50155*, EN 50121-3-2, EN 50121-4. Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details. *Complies with a portion of EN 50155 specifications. |
• Warranty | |
Warranty Period | 5 years |